top of page

The CPI POPR® pop open pressure relief valve is designed to replace atmospheric rupture assemblies, being automatically activated when the divider block system over pressures.

 

PART NO.                                                              DESCRIPTION

65005000POPR35A           POPR 3,500 psi (241 bar) with NPT elbow & outlet fittings

65005000POPR55A           POPR 5,500 psi (379 bar) with NPT elbow & outlet fittings

 

 

TECHNICAL SPECIFICATIONS

Inlet Thread: 1/8” NPT Male

Outlet Thread: 1/4” Tube Fitting

 

FEATURES

• Environment - eliminates oil spills on compressor skid

• Safety - protects a technician from possible injury caused by high pressure oil squirting from a blown rupture disc

• Reliability - opens at a specific set pressure to protect compressor from damage

• Protection - remains in open position after system over pressures, until reset by a technician with a simple push on the bottom of the POPR® valve

• Guaranteed - works with and can be easily fitted to all divider block systems

• Solves - the problems associated with all atmospheric rupture assemblies and potential damage to a compressor

 

CPI/PREMIER POPR POP OPEN PRESSURE RELIEF VALVE

SKU: 356845621444
$650.00Price
Quantity
  • INSTALLATION PROCEDURE

    Most compressors have a tubing “T” installed in the discharge line of the lubricator pump with the atmospheric rupture assembly pointing down. 1. Remove the atmospheric assembly from the tubing “T” 2. Screw the 1/8” male end of the POPR valve into the tubing “T” 3. Connect 1/4” tubing to the tube fitting included with the POPR® valve 4. Run tubing from the POPR valve to any convenient area into the vent on the lube box, waste disposal area, into compressor frame etc

    For late model compressors you can do the following: Remove the existing tube fittings and install a new tubing “T”. Then follow instructions 2 through 4 above or to allow your operators to easily monitor system pressure and easily install the POPR valve. CPI has a complete suction and discharge manifold assembly kit that contains liquid filled pressure gauges, purge ports, and all fittings. The kit is the latest technology and comes complete with the POPR’s valve to install on your existing single and dual pump systems.

    For all other industry compressors: Remove the atmospheric rupture assembly and install the POPR® valve per the instructions 2 through 4 above.

  • RETURN & REFUND POLICY

    Thank you for shopping at Smith's Technical Services! We offer refund and/or exchange within the first 15 days of receiving your purchase, if 15 days have passed, you will not be offered a refund and/or exchange of any kind. Your item must be unused and in the same condition that you received it. If you need to return something please reach out for an RMA before doing so. Packages without an RMA will be rejected. Returned items may be subject to a 15% restock fee.

  • SHIPPING INFO

    Thank you for your order, please allow 2-3 days for your order to ship. If we do not have enough stock or are having delays on any of the products ordered we will contact you by phone or email. Shipping charges are basic rates, orders leaving the United States are subject to an additional charge. If additional export charges are needed, we will reach out by phone or email. We will not process or ship any order until additional charges are paid. Please notify Smith's Technical Services right away if any damage should occur during transit so we can reach out to carrier. We will also need at least 4-5 pictures of the damage, upon waiting for response from carrier please keep all packaging until case is resolved.